Installation and programming Instructions
Default settings on power up
I have an omnicron 9000 alarm system but i have lost the user manual. Does anyone know where i could get one please? I have an omnicron 9000 alarm system but i. Manual for cleaning the coils. For installations within a kilometre of the coast, use of the accessory is strongly recommended Coil treated with anti-corrosion paints. The fans are axial fans, directly coupled to a three-phase 6-pole electric motor, with integrated thermal overload protection (klixon) and IP 54 protection rating.
User code 1234
Part set code 0000
Engineer code 9999
Cleaner code 7777
Exit time 30sec
Entry time 30sec
Bell Time 20min
Speaker time 20min
User reset YES
Relay activation in part set YES
Mains LED OFF (when armed)
PA (sounder & relay) NOT SILENT
Auto re-arm YES
Bell delay OFF (0sec)
Speaker delay OFF (0sec)
Zone 1 E/E in part set YES
Intermediate zones NONE
Part set zones NONE
Self-monitoring zones NONE
Double knock NO
To Enter ENGINEER MODE
Press Reset key and enter current user code (1234) Then press program.
Green CLEAR led will flash.
Enter 99 then current eng. code (9999)
Red ENGINEER LED will flash continuously, indicating the panel is in engineer mode.
Omicron High Level Alarm Manual
YOUR NOW IN ENGINEER MODE.
If a mistake is made in programming, press the RESET key twice and start again. Dp gympac manual.
ENTRY TIME
Enter Eng Mode Enter 30
Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=10sec; 02=20sec and so on).
EXIT TIME
In ENG MODE Enter 31
Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=10sec; 02=20sec and so on).
Omnicron Alarm Manual Instructions
BELL TIME In ENG MODE Enter 21
Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=5min; 02=10min and so on).
BELL DELAY
In ENG MODE Enter 20
Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=2min; 02=4min and so on).
SPEAKER DURATION In ENG MODE
Enter 23
Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=5min; 02=10min and so on).
SPEAKER DELAY In ENG MODE Enter 22
Omnicron Alarm Manual 2017
Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=2min; 02=4min and so on).
AUTO RE-ARM ON (factory set on)
In ENG MODE
Omnicron 7000 Alarm Manual
Enter 14 ( system will re-arm when bell stops)
Omnicron Alarm Manual Pdf
AUTO RE-ARM OFF