9000 series

Installation and programming Instructions

Default settings on power up

I have an omnicron 9000 alarm system but i have lost the user manual. Does anyone know where i could get one please? I have an omnicron 9000 alarm system but i. Manual for cleaning the coils. For installations within a kilometre of the coast, use of the accessory is strongly recommended Coil treated with anti-corrosion paints. The fans are axial fans, directly coupled to a three-phase 6-pole electric motor, with integrated thermal overload protection (klixon) and IP 54 protection rating.

User code 1234

Part set code 0000

Engineer code 9999

Cleaner code 7777

Exit time 30sec

Entry time 30sec

Bell Time 20min

Speaker time 20min

User reset YES

Relay activation in part set YES

Alarm

Mains LED OFF (when armed)

PA (sounder & relay) NOT SILENT

Auto re-arm YES

Bell delay OFF (0sec)

Speaker delay OFF (0sec)

Zone 1 E/E in part set YES

Intermediate zones NONE

Part set zones NONE

Self-monitoring zones NONE

Double knock NO

To Enter ENGINEER MODE

Press Reset key and enter current user code (1234) Then press program.

Green CLEAR led will flash.

Enter 99 then current eng. code (9999)

Red ENGINEER LED will flash continuously, indicating the panel is in engineer mode.

Omicron High Level Alarm Manual

YOUR NOW IN ENGINEER MODE.

If a mistake is made in programming, press the RESET key twice and start again. Dp gympac manual.

ENTRY TIME

Manual

Enter Eng Mode Enter 30

Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=10sec; 02=20sec and so on).

EXIT TIME

In ENG MODE Enter 31

Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=10sec; 02=20sec and so on).

Omnicron Alarm Manual Instructions

BELL TIME In ENG MODE Enter 21

Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=5min; 02=10min and so on).

BELL DELAY

In ENG MODE Enter 20

Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=2min; 02=4min and so on).

SPEAKER DURATION In ENG MODE

Enter 23

Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=5min; 02=10min and so on).

SPEAKER DELAY In ENG MODE Enter 22

Omnicron Alarm Manual 2017

Two LED’s show (indicating that two keys are to be pressed) Enter new time in seconds (01=2min; 02=4min and so on).

AUTO RE-ARM ON (factory set on)

In ENG MODE

Omnicron 7000 Alarm Manual

Enter 14 ( system will re-arm when bell stops)

Omnicron Alarm Manual Pdf

AUTO RE-ARM OFF